• Not Registered?

          No Problem!

          Take Me To

          Register

        • Welcome Back!

          Let's start making reports

          Take Me To

          Log In

        • View

          My Account

  • LOG IN
        • Already Registered?

          Take Me To

          Log In

        • Want Fast Reports?

          You're just a click away

          Take Me To

          Register

        • Easy

          Fast

          Safe

  • REGISTER
        • 4

          Easy Steps

          To Create Your Report

        • 1

          Enter Site Details

          2

          Select Report Type

          3

          Select Optional Components

          4

          Print or Download

        • Ok, Got It!

          Let's Begin

          Create

          New Report

  • CREATE REPORTS
        • 24/7

          Access 

          Edit Any Time

        • Safe & Secure

          Ready To Edit Whenever You Are...

        • Go To

          My Reports

  • EDIT REPORTS

Tricel Wastewater Treatment for site recommendation reports

The range of EPA CoP compliant Tricel wastewater treatment solutions

Solutions that can be specified by the Tricel Site Assessor website.

See below a list of each Environment Protection Agency (EPA) Code of Practice (CoP) compliant wastewater treatment system that Tricel Site Assessor will, in less than 5 mins, provide a detailed specification for, are listed below:

You can also read more about each Tricel product on our dedicated product page.

Tricel Site Assessor can specify SEVEN wastewater treatment system types (primary, secondary & tertiary), generate a detailed report and drawings specifying the system requires and this can be inserted directly into a planning application.

The site has been designed to suit your needs and allow you to compare systems and edit existing reports.

How to create a site recommendation report with a Tricel wastewater treatment system?

The site recommendation reports generated on Tricel Site Assessor specify the exact system details that are required for planning applications.

Simply enter your client & site details and select the types of Tricel wastewater treatment solution adapted to the project. This report is then ready to be integrated into site recommendation report of the planning application.

Seven Tricel wastewater treatment system types available on Tricel Site Assessor, including primary, secondary and tertiary treatment

1. Septic tank and percolation area

Recommendation for a Tricel septic tank with percolation area.

Requirements:

You are required to insert the following site-specific information:

  • T/P Value
  • PE Value
Septic tank and percolation area

2. Wastewater treatment plants and gravity or pumped soil polishing filter

Recommendation for a Tricel Novo wastewater treatment plant (gravity or pumped) with a soil polishing filter as a form of secondary treatment.

Requirements:

You are required to insert the following site-specific information:

  • PE value
  • T/P value
  • Select Pumped or Gravity outlet
    • If Outlet is Pumped, please insert the following:
      • Length of the rising main
      • Height difference in the rising main (static head)
Wastewater treatment plants and gravity or pumped soil polishing filter

3. Wastewater treatment plants and pressurised soil polishing filter

Recommendation for a Tricel Novo wastewater treatment plant with a pressurised soil polishing filter as a form of secondary treatment.

Requirements:

You are required to insert the following site-specific information:

  • Length of the rising main
  • Height difference in the rising main (static head)
  • Select a preferred soil polishing filter (pressurised) supplier (Ashtec or Munster)
  • T/P value
  • PE value
Wastewater treatment plants and pressurised soil polishing filter

4. Wastewater treatment plants and sand polishing filter

Recommendation for a Tricel Novo wastewater treatment plant with a Sandcel sand polishing filter as a form of tertiary treatment.

Requirements:

You are required to insert the following site-specific information:

  • Length of the rising main
  • Height difference in the rising main (static head)
  • T/P value
  • PE value

 

Wastewater treatment plants and sand polishing filter

5. Septic tank with Tricel Puraflo and percolation area

Recommendation for a Tricel septic tank with a Tricel Puraflo and a percolation area as a form of secondary treatment.

Requirements:

You are required to insert the following site-specific information:

  • Length of the rising main
  • Height difference in the rising main (static head)
  • T/P value
  • PE value
 Septic tank with Tricel Puraflo and percolation area

6. Wastewater treatment plant with Puraflo

Recommendation for a Tricel Novo wastewater treatment plant with Tricel Puraflo as a form of tertiary treatment.

Requirements:

You are required to insert the following site-specific information:

  • Length of the rising main
  • Height difference in the rising main (static head)
  • T/P value
  • PE value

 

Wastewater treatment plant with Puraflo

7. Septic tank with Puraflo and soil polishing filter

Recommendation for a septic tank with a Tricel Puraflo and a soil polishing filter as a form of secondary treatment.

Requirements:

You are required to insert the following site-specific information:

  • Length of the rising main ?
  • Height difference in the rising main (static head) ?
  • T/P value
  • PE value

Septic tank with Puraflo and soil polishing filter

Once the system type suitable for the site conditions has been determined during the Site Suitability Assessment, the corresponding system on Tricel Site Assessor can now be selected and a site recommendation report will be generated and emailed to you to integrate into planning application.

Finally, you can also compare systems and edit existing reports for a site recommendation report that have been previously created.

Still not sure how to use Tricel Site Assessor? Download our ebook.